- Ducting, Diffuser and Accessories
- Packaged Outdoor
- Split Systems and Condensers
- Actuator
- Air Compressor Parts, Components and Accessories
- Air Cond Bracket
- Air Conditioner Sensor
- Air Conditioning Control System
- Air Cooled Chiller
- Air Cooler
- Air Filters
- Air Handlers
- Air Handling System
- Air Swing Motor
- Air Swing Motor (Small)
- Air Terminals HVAC
- Air-Cond and Refrigeration Tooling
- Air-Conditioner Unit
- Anti Clog
- Automatic Drain Valve
- Belting
- Brazing Equipment & Accessories
- Carrier Parts
- Chemicals
- Chilled and Induction Beams
- Chiller Components
- Chiller Parts
- Actuators
- Bearings and Bushing
- Compressors
- Contactors
- Electronic Components
- Fans and Fan Blower Parts
- Filters and Filter Parts
- Gaskets
- Miscellaneous Electrical Parts
- Miscellaneous Fasteners and Fittings
- Miscellaneous Valves
- Motors
- O - Rings
- Oil and Fluids
- Preventive Maintenance Kits
- Pump
- Relays
- Relief Valves
- Repair Parts Kits
- Solenoid Valves
- Switches
- Thermal Expansion Valves
- Transducers
- View All
- Cleaning Equipment & Tools
- Cold Room Parts and Accesories
- Commercial Chiller Components
- Component
- Compressor
- Compressor Accessories
- Condensate Drainage Pump
- Condensing Unit
- Cooling Coil
- Cooling Tower Spare Part
- Copper and Fittings
- Copper Piping Leak Test
- Coupling
- Daikin /Acson / York Spare Parts
- Electrical
- Electronic Air Cleaner
- FAN BLADE / FAN PROPELLER
- Fan Coils
- Fan Motor
- Fan Set
- Filter Aircond
- Fire Duct Systems
- FRIDGE & REFRIGERATOR PARTS
- Hardware Items and Tools
- Induction Units
- Innerco Piercing Valve
- Insulation
- Lubricant Oil and Equipment
- Measuring Instrument
- Packaged Indoor
- PCB Board
- Pressure Test Equipment and Accessories
- Purifier Series
- Refrigerant
- Sensors
- Silicone Sealant
- Spray Pump
- Temperature / Humidity Display & Controller
- Underfloor Air Distribution
- Unit Ventilators
- Vacuum Pump
- Valve (Water/Steam Application)
- Water Cooled Chiller
- York Chiller Parts
- Others
- Others
United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-5992610
PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-491 2610
CO2 8322 Room Sensor with Temperature NSA-CO2-ROOM
Previous | 2 / 5 | Next |
- Air Conditioner Sensor Malaysia
- Carrier NSA Series Sensors Malaysia
- Carrier Sensor Accessories Malaysia
- Carrier Non-Communicating Sensors Malaysia
- NSA-HH/CO2-R2-CP-C NSA-HH/CO2-R2O-CP-C NSA-HH/CO2-R2SO-CP-C
Part Numbers
NSA-HH/CO2-R2-CP-C
NSA-HH/CO2-R2O-CP-C
NSA-HH/CO2-R2SO-CP-C
The Carrier Carbon Dioxide Room Series Sensor with Temperature, Setpoint, and Override monitors the carbon dioxide (CO₂) levels in commercial, school, and office-type environments. The concentration of CO₂ is a strong indication of the overall indoor air quality. The NSA-HH/CO2-R2 Series is based on a single beam, non-dispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide levels for building climate control. In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs.
Applications
Schools, Office Buildings, Auditoriums, Gymnasiums, Shopping Malls, Theatres, Demand Control Ventilation & Economizers
Supply Voltage: | 24 VAC +/-20%, 50/60 Hz (half-wave rectifier) | 16.5-40 VDC Max |
Power Consumption: | 3 VA for 24 VAC, 3W for 24 VDC (peak); <0.9W (average) |
Sensing Technology: | Single beam infrared sensing technology (NDIR) |
Sensing Method: | Diffusion |
Measurement Range Default: | 0 to 2,000 ppm |
Extended CO₂ Ranges: | Up to 10,000 ppm (factory set) |
Extended Range Accuracy: | +/- 30 ppm and +/- 5% of reading |
CO₂ Output Signal: | Output 1: 0-5 VDC or 0-10 VDC (Default) | Output 2: 4-20 mA (500 Ohm Load maximum) |
Fail Safe: | Polarity protected |
CO₂ Accuracy1: | +/- 40 ppm +/- 3% of reading (@ 15-35°C; 20-70% RH and 101.3 kPa) |
Pressure Dependence: | + 1.6% reading per kPa (deviation from standard pressure 101.3 kPa) |
Response Time: | ≤2 minutes, diffusion |
Warm-Up Time: | < 1 minute (@ full specs < 15 minutes) |
Temperature Accuracy: | +/- 1°F (+/- 0.6ºC) |
Operating Temperature Range: | 32 to 122ºF (0 to 50ºC) |
Operating Humidity Range: | 0 to 95%, non-condensing |
Enclosure: | ABS, Plastic, White, UL94-HB |
Sensor Coverage Area: | 7,500 sq. ft maximum |
Mounting Height: | 4-6 ft |
Sensor Life2: | > 15 years (typical) |
Calibration3: | ABC algorithm (Automatic Baseline Correction) |
Product Dimensions: | (H) 4.50'' (114.30 mm) x (W) 2.75'' (69.85 mm) x (D) 1.12'' (28.45 mm) |
Product Weight: | 0.230 lbs (0.104 kg) |
Agency Approvals: | EMC Directive 2014/30/EC | RoHS Directive 2011/65/EU |