- Ducting, Diffuser and Accessories
- Packaged Outdoor
- Split Systems and Condensers
- Actuator
- Air Compressor Parts, Components and Accessories
- Air Cond Bracket
- Air Conditioner Sensor
- Air Conditioning Control System
- Air Cooled Chiller
- Air Cooler
- Air Filters
- Air Handlers
- Air Handling System
- Air Swing Motor
- Air Swing Motor (Small)
- Air Terminals HVAC
- Air-Cond and Refrigeration Tooling
- Air-Conditioner Unit
- Anti Clog
- Automatic Drain Valve
- Belting
- Brazing Equipment & Accessories
- Carrier Parts
- Chemicals
- Chilled and Induction Beams
- Chiller Components
- Chiller Parts
- Actuators
- Bearings and Bushing
- Compressors
- Contactors
- Electronic Components
- Fans and Fan Blower Parts
- Filters and Filter Parts
- Gaskets
- Miscellaneous Electrical Parts
- Miscellaneous Fasteners and Fittings
- Miscellaneous Valves
- Motors
- O - Rings
- Oil and Fluids
- Preventive Maintenance Kits
- Pump
- Relays
- Relief Valves
- Repair Parts Kits
- Solenoid Valves
- Switches
- Thermal Expansion Valves
- Transducers
- View All
- Cleaning Equipment & Tools
- Cold Room Parts and Accesories
- Commercial Chiller Components
- Component
- Compressor
- Compressor Accessories
- Condensate Drainage Pump
- Condensing Unit
- Cooling Coil
- Cooling Tower Spare Part
- Copper and Fittings
- Copper Piping Leak Test
- Coupling
- Daikin /Acson / York Spare Parts
- Electrical
- Electronic Air Cleaner
- FAN BLADE / FAN PROPELLER
- Fan Coils
- Fan Motor
- Fan Set
- Filter Aircond
- Fire Duct Systems
- FRIDGE & REFRIGERATOR PARTS
- Hardware Items and Tools
- Induction Units
- Innerco Piercing Valve
- Insulation
- Lubricant Oil and Equipment
- Measuring Instrument
- Packaged Indoor
- PCB Board
- Pressure Test Equipment and Accessories
- Purifier Series
- Refrigerant
- Sensors
- Silicone Sealant
- Spray Pump
- Temperature / Humidity Display & Controller
- Underfloor Air Distribution
- Unit Ventilators
- Vacuum Pump
- Valve (Water/Steam Application)
- Water Cooled Chiller
- York Chiller Parts
- Others
- Others
United Faith Sdn Bhd (HQ)
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.
+6012-2631315
+6012-5992610
+6012-5992610
PJ Branch :
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.
+6012-491 2610
i-Vu® VAV Zone II Secondary Terminal OPN-SECTRM-02
Previous | 10 / 29 | Next |
- Carrier Air Conditioner Control System Malaysia
- Carrier i-Vu Controllers Malaysia
- Carrier Air Conditioner Controllers Malaysia
- Carrier HVAC Controllers Malaysia
- Carrier VAV Zone II Secondary Terminal OPN-SECTRM-02 Malaysia
Product Integrated Controller
The VAV Zone II Secondary Terminal controller provides control of a secondary zone damper where CFM measurement is required. This advanced controller features a separable actuator for easy installation onto a zone damper. It requires connection to the programmable Carrier Zone Controller (OPN-B3-P-02) for proper operation.
Application Features
- Dual Duct - Hot Deck/Cold Deck control
- DOAS applications
- Quick and easy test & balancing process
System Benefits
- Fully plug-and-play with the Carrier i-Vu Building Automation System
- Connects directly to the ACTnet bus on Carrier ZoneCtrl II programmable zone controller
Hardware Features
- Separate brushless actuator for reliability and longevity
- ACTnet communications bus
- Precision differential pressure sensor
Communication Ports | ACTnet Port: For connecting the actuator cable and to the ZoneCtrl II |
Separable Actuator | Brushless DC motor, torque 45 inch-pounds (5Nm), runtime 205 seconds for 90 degree travel during control. |
Integral Pressure Sensor | Precision low flow AWM series O-2 in H2O, sensitive down to +/-0.001 in. H2O. Barbed tapered airflow connections accept 3/16 in. (4.75 mm) ID tubing. Allows for readings across the 0-2 in H2O range, accurate to +/-5% of full flow at 2 in. H2O. |
Protection | Incoming power and network connections are protected by non-replaceable internal solid state polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input and output connections are also protected against voltage transient and surge events. |
Status Indicators | LED status indicators for run status, error, power and motor direction |
Listed by | UL-916 (PAZX), cUL-916 (PAZX7), FCC Part 15-Subpart B-Class A, CE EN50082-1997, UL94-5VA plenum rated enclosure |
Environmental Operating Range |
Operating: 32° to 130°F (0° to 54°C) 10 to 90% RH, non-condensing Storage: -24° to 140°F (-30° to 60°C) 10 to 90% RH, non-condensing |
Power Requirements | 24VAC +/- 10%, 50-60Hz, 14 VA power consumption, 26VDC (25V min, 30V max), single class 2 source only, 100 VA or less |